Advertisement

毅丰
2017.06.29
受控正本
MP-400Z IP

User Manual

Please read the instructions carefully before use

Advertisement

Table of Contents
loading

Summary of Contents for ACME MP-400Z IP

  • Page 1: User Manual

    毅丰 2017.06.29 受控正本 MP-400Z IP User Manual Please read the instructions carefully before use...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. Safety Instructions ........................2 2. Techical Specfications ........................ 4 3. How To Set The Fixture ......................5 3.1 Control Panel ........................... 5 3.2. Main Functions ........................6 4.How To Control The Unit ......................11 4.1 Master/Slave Built In Preprogrammed Function ..............12 4.2 DMX Controller ........................
  • Page 3: Safety Instructions

    1. Safety Instructions Please read the instructions carefully which include important information about installation, operation WARNING maintenance.  Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Caution:...
  • Page 4  Do not touch any wire during operation as there might be a hazard of electric shock.  Avoid power wires together arounding other cables.  In the event of serious operating problem, stop using the unit immediately.  Never turn on and off the unit time after time. ...
  • Page 5: Techical Specfications

    2. Techical Specfications DMX Channel: 5 CH/ 7 CH/ 9 CH channels  Control Mode: DMX512,RDM  Firmware Upgrade: Update via DMX link  Display: OLED display  Data In/Out: 5-pin IP XLR  Power In/Out: IP connector  Protection Rating: IP65 ...
  • Page 6: How To Set The Fixture

    3. How To Set The Fixture 3.1 Control Panel 1. Display To show the menu and the selected functions 2. Button: MENU To select the programming functions DOWN To go backward in the selected functions To go forward in the selected functions ENTER To confirm the selected functions 3.
  • Page 7: Main Functions

    3.2. Main Functions To select any functions, press the MENU button until the required one is shown on the display. Select the function by the ENTER button and the display will blink. Use the DOWN and UP button to change the mode. Once the required mode has been selected, press the ENTER button to setup or it will automatically return to the main functions without any change after idling one minute.
  • Page 9 DMX Setting To select DMX Setting press the ENTER button to confirm, use the UP/DOWN button to select DMX Address or Channel Mode. DMX Address —DMX512 address setting To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to adjust the address from 001 to 512, press the ENTER button to store.
  • Page 10 menu mode. Mode 1 (Optically Linear): The increase in light intensity appears to be linear as DMX value is increased. Mode 2 (Square Law): Light intensity control is finer at low levels and coarser at high levels. Mode 3 (Inverse Square Law): Light intensity control is coarser at low levels and finger at highlevels.
  • Page 11: Manual Mode

    Auto Test Select Auto Test, press the ENTER button to confirm, the unit will run built-in programs to automatically test. Press the MENU button back to the last menu or exit menu mode after auto test. Manual Mode Enter menu mode, select Manual Mode press the ENTER button to confirm, use the UP/DOWN button to select Dimmer, Strobe, Red, Green, Blue, White or Zoom.
  • Page 12: How To Control The Unit

    Fixture Information Enter menu mode, select Fixture Information, press the ENTER button to confirm, use the UP/DOWN button to select LED Temperature, Fixture use time, Light On time or Firmware Version. LED Temperature Select LED Temperature, press the ENTER button to confirm, LED temperature will show on the display, press the MENU button to exit.
  • Page 13: Master/Slave Built In Preprogrammed Function

    4.1 Master/Slave Built In Preprogrammed Function By linking the units in master/slave connection, the first unit will control the other units to give an automatic, sound activated, synchronized light show. This function is good when you want an instant show. You have to select show for the first unit. Its DMX input jack will have nothing plugged into.
  • Page 14 All LED Blue 000-255 0-100% All LED White 000-255 0-100% Zoom 000-255 0-100% 7 Channels mode: CHANNEL VALUE FUNCTION All LED Red 000-255 0-100% All LED Green 000-255 0-100% All LED Blue 000-255 0-100% All LED White 000-255 0-100% Dimmer 000-255 0-100% Strobe...
  • Page 15 187-214 Fast open slow close 215-223 Random fast open slow close 224-250 Slow open slow close 251-255 Open Zoom 000-255 0-100% 9 Channels mode: CHANNEL VALUE FUNCTION All LED Red 000-255 0-100% All LED Green 000-255 0-100% All LED Blue 000-255 0-100% All LED White...
  • Page 16 151-178 Slow open fast close 179-186 Random slow open fast close 187-214 Fast open slow close 215-223 Random fast open slow close 224-250 Slow open slow close 251-255 Open Zoom 000-255 0-100% Macro Color For All LED 000-009 Open (RGBW color mixing enabled) 010-014 LEE 790 –...
  • Page 17 105-109 LEE 124 – Dark Green 110-114 LEE 139 – Primary Green 115-119 LEE 089 – Moss Green 120-124 LEE 122 – Fem Green 125-129 LEE 738 – JAS Green 130-134 LEE 088 – Lime Green 135-139 LEE 100 – Spring Yellow 140-144 LEE 104 –...
  • Page 18: Dmx512 Connection

    4.4 DMX512 Connection Termination reduces signal errors and to avoid signal transmission problems and interference. It is always advisable to connect a DMX terminal. Put a resistance (120 ohm 1/4W) between pin 2(DMX-) and pin3 (DMX+) of the last fixture. 1.
  • Page 19: Troubleshooting

    5. Troubleshooting Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting: A. The unit does not work, no light and the fan does not work 1. Check the connection of power and main fuse. 2.
  • Page 20: Declaration Of Conformity

    Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC. EN55103-1: 2009 ; EN55103-2: 2009; EN62471: 2008; EN61000-3-2: 2006 + A1:2009 + A2:2009; EN61000-3-3: 2008. &...

This manual is also suitable for:

Stage par 400 zoom ip

Table of Contents