    Menu 1. Safety Instructions ..........................1 2. Technical Specifications ........................3 3. Installation and Connection ......................5 4. How to set the unit ...........................6 4.1 Rear Panel ............................6 4.2 Main Function..........................7 5. How to control the unit ........................11 6. DMX512 configuration ........................12 7. DMX512 Connection........................12 8.Troubleshooting ..........................13 9.
  • Page 3: Safety Instructions

    1. Safety Instructions Please read the instruction carefully which includes important information about the installation, usage and maintenance. WARNING  Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet. ...
  • Page 4: Technical Specifications

    2. Technical Specifications  1/2 channel Mode;  Dimmer, Strobe;  Ideal for Professional stages, Concerts, clubs, discotheques, Mobile DJs, etc.  Input Voltage: AC100V~240V,50/60Hz  Total Power consumption: 105W  Beam Angle: 9°/15°/20°/25°/30°  IP Grade: IP 20  LED Sources: 98 W COB ...
  • Page 6: Installation And Connection

    Installation and Connection The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture.
  • Page 7: How To Set The Unit

    4. How to set the unit 4.1 Rear Panel Display: Show the various menus and the selected functions; ○ ○ 2 LED indicator: POWER Power On DMX input present ○ 3 Button: MENU To select the programming functions DOWN To go forward in the selected functions To go backward in the selected functions ENTER To confirm the selected functions...
  • Page 8: Main Function

    ○ 5 Mains input/output::Use Powercon true one mains connection. DMX input/output: ○ For DMX512 link, use 5-pin XLR plug cable to input DMX signal, and to link the next unit. The beam angle can be adjusted manually, which is 9°/15°/20°/25°/30°. 4.2 Main Function To select any functions, press MENU button until the required one is shown on the display.
  • Page 9: Channel Mode

    DMX 512 Address Setting Select the , press the ENTER button and the display will blink. Use the DOWN and UP button to change the DMX 512 address ( 001-512) . Once the address has been selected, press the ENTER button to setup or exit menu mode without any change after 8 seconds automatically.
  • Page 10 Mode 1)… (Dimmer Mode 4). Once selected, press the ENTER button to setup or exit menu mode without any change after 8 seconds. Back to the functions without any change press the MENU button again. Dimmer mode 1 Dimmer mode 2 Dimmer mode 3 Dimmer mode 4 Optically Linear...
  • Page 11 Display Inverse Select the , press the ENTER button. Use the DOWN and UP button to select (Display Normal) or (Display Inverse). Once selected, press the ENTER button to setup or exit menu mode without any change after 8 seconds automatically. Back to the functions without any change press the MENU button again.
  • Page 12: How To Control The Unit

    Software Version , press ENTER button and the display will show the version of software of the unit. Select the To go back to the functions press the MENU button. 5. How to control the unit 1. By DMX controller; No need to turn the unit off when you change the DMX address, as new DMX address setting will be affected at once.
  • Page 13: Dmx512 Configuration

    6. DMX512 configuration Channel Mode: 7. DMX512 Connection Mode connection: 1. Connect the fixture together in a “daisy chain” by XLR plug cable from the output of the fixture to the input of the next fixture. The cable cannot be branched or split to a “Y” cable. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down...
  • Page 14: Troubleshooting

    the system 2. The DMX output and input connectors are pass-through to maintain the DMX circuit when one of the units’ power is disconnected. 3. At last fixture, the DMX cable has to be terminated with a terminator to reduce signal errors. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
  • Page 15: Fixture Cleaning

    9. Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture’s optics. ...
  • Page 16 Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 2004/108/EC. EN55103-1: 2009 ; EN55103-2: 2009; EN61000-3-2: 2006 + A1:2009 + A2:2009; EN61000-3-3: 2008. &...