Diagnostics - Datalogic MATRIX 210 Programming Manual

Host mode programming
Hide thumbs Also See for MATRIX 210:
Table of Contents

Advertisement

4

4.16 DIAGNOSTICS

25 PIN CONNECTOR MODELS
ETHERNET MODELS
PARAMETER
HEARTBEAT
Status
DIAGNOSTICS
Status
Refresh Time (sec)
Slave Diagnostics
(Master/Slave)
Slave Diagnostics
(ID-NET Network)
Local Network Failure
LEDs Activation On
Slave Failure
(Master/Slave)
LEDs Activation On
Slave Failure
(ID-NET Network)
FieldBus
Communication Failure
FieldBus Type Mismatch 1
FieldBus Configuration
Error
Fieldbus DHCP Problem
Wrong Rotary Switch
Selection
CBX BM100
Communication Failure
ACTIONS
Heartbeat TX Mode
Heartbeat TX Timeout
(sec)
TX Mode
Message Position
66
TYPE
SEL
STRING
1
1
ESC T k
1
1
ESC T A
1
1
ESC T B
1
1
ESC T C
1
1
ESC T D
1
1
ESC T E
1
1
ESC T F
1
1
ESC T G
1
1
ESC T H
1
ESC T I
1
1
ESC T J
ESC T K
1
1
ESC T L
1
1
ESC T M
1
1
ESC T l
1
1
ESC T m
1
1
ESC T Q
1
1
ESC T R
HOST MODE PROGRAMMING
DATA
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = 1
1 = 2
2 = 5
3 = 10
4 = 30
5 = 60
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
0 = Conditioned
1 = Unconditioned
0 = 1
1 = 2
2 = 5
3 = 10
4 = 30
5 = 60
6 = 180
0 = On Timeout
1 = With Code
0 = Append to Code
1 = Replace Code

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents