2
DESCRIPTION
4
Button Function 4
After entering this command during the programming session, the reader starts the
function associated with the F4 button position. Entering the same command again
will cause the reader to exit from the procedure.
If the programming command is correct, the device confirms with the first reply
message. If programming command is wrong (i.e. a typing error in the programming
string) or due to a transmission error, Matrix replies with the second error message.

2.5 OTHER FUNCTIONS

DESCRIPTION
1
Disable All Symbologies
After entering this command during the programming session, the reader disables
all the symbologies in permanent memory.
If the programming command is correct, the device confirms with the first reply
message. If programming command is wrong (i.e. a typing error in the programming
string) or due to a transmission error, Matrix replies with the second error message.
2
Restore Default
After entering this command during the programming session, the reader restores the
factory default parameters in permanent memory.
If the programming command is correct, the device confirms with the first reply
message. If programming command is wrong (i.e. a typing error in the programming
string) or due to a transmission error, Matrix replies with the second error message.
4
HOST COMMAND
<ESC> 3 <ESC>
I C #
HOST COMMAND
<ESC> 4 <ESC>
I C #
<ESC> 5 <ESC>
I C #
HOST MODE PROGRAMMING
REPLY MESSAGE
<ESC> K <CR><LF> <ESC> W
1 <CR><LF>
REPLY MESSAGE
<ESC> K <CR><LF>
<ESC> W 1 <CR><LF>
<ESC> K <CR><LF> <ESC> W
1 <CR><LF>