PROGRAMMING STRINGS

3 PROGRAMMING STRINGS

3.1 DEFINITIONS

Common definitions for each parameter are:
Depth (parameter depth)
Parameter depth indicates if the parameter is made up of a vector of values or a single value
(e.g. Gain parameter has depth > 1 since we have one Gain value for each recipe allowed;
Operating Mode parameter has depth =1).
Depth must be specified when preparing the escape programming string.
Example: Image Acquisition Setting #3 enable/disable.
Label:
Escape Sequence
Type (parameter type)
Parameter type is essential in order to decide the features of the serial command used to set
its new value. Types are:
Type
0:
Integer (numeric)
Type
1:
Enumerative
Type
2:
String
Type
3:
Bit Field
Type
4:
At Least One
Label
Information available in the Parameters window of the VisiSet™ configuration tool.
The other definitions change according to the parameter type.
Integer (Type = 0)
Range
Minimum and maximum values allowed for the parameter.
Default
Default value (integer).
Image Acquisition Setting
<ESC> a #n [selection]
3