Datalogic MATRIX 210 Programming Manual page 27

Host mode programming
Hide thumbs Also See for MATRIX 210:
Table of Contents

Advertisement

MATRIX 210™ PARAMETERS LIST
PARAMETER
Reading Phase OFF
Reading Phase Timeout
(ms)
Timeout Counting From 1
Acquisition Trigger (One
Shot)
First Acquisition Setting
Used
Number of Image Slots
Code Filter Depth
Code Filter Selection
Good Read Threshold
No Read Threshold
Timeout Threshold
(sec)
ACQUISITION TRIGGER DELAY (DEPTH: n = 1 to 10)
Status #n
Delay Time #n (x100
s)
Special characters <FE
programming string to indicate parameter Depth > 9. Refer to paragraph 3.2
for further details.
NOTE
TYPE
SEL
STRING
4
11
ESC A D
0
ESC A E
1
ESC A N
4
7
ESC A F
1
1
ESC A H
0
ESC A L
0
ESC A I
1
1
ESC A N
0
ESC A J
0
ESC A K
0
ESC A O
1
1
ESC n #n
0
ESC o #n
> and <FD
H
DATA
1 = Ext. Trig. Leading Edge
2 = Ext. Trig. Trailing Edge
4 = Main Port String
8 = Auxiliary Port String
16 = Input 2 Leading Edge
32 = Input 2 Trailing Edge
64 = Timeout
128 = Complete Read
256 = Ethernet String
512 = Ethernet IP Input Leading Edge
1024 = Ethernet IP Input Trailing Edge
2048 = Fieldbus String
4096 = Fieldbus Input Leading Edge
8192 = Fieldbus Input Trailing Edge
16834 = ID-NET String
Range: 17 to 60000
0 = Reading Phase ON
1 = Reading Phase OFF
1 = Ext. Trig. Leading Edge
2 = Ext. Trig. Trailing Edge
4 = Main Port String
8 = Auxiliary Port String
16 = Ethernet String
32 = Ethernet IP Input Leading Edge
64 = Ethernet IP Input Trailing Edge
128 = Fieldbus String
256 = Fieldbus Input Leading Edge
512 = Fieldbus Input Trailing Edge
1024 = ID-NET String
0 = First Enabled
1 = Last Successful
Range: 1 to 300
Range: 0 to 5
0 = Acquisition Counter Threshold
1 = Timeout Threshold
Range: 0 to 100000
Range: 0 to 100000
Range: 0 to 300
(0 = Disabled)
0 = Disabled
1 = Enabled
Range: 0 to 100000
> must be added after #n in the
H
4
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents