4
4 MATRIX 210™ PARAMETERS LIST

4.1 OPERATING MODE

25 PIN CONNECTOR MODELS
ETHERNET MODELS
PARAMETER
OPERATING MODES
Operating Mode
Reading Phase ON
Acquisition Trigger
(Phase Mode)
Acquisition Trigger
Status
Acquisition Trigger
Period (ms)
(Phase Mode)
22
TYPE
SEL
STRING
1
1
ESC A A
4
9
ESC A B
4
10
ESC A C
1
1
ESC A P
0
ESC A G
HOST MODE PROGRAMMING
DATA
0 = One Shot
1 = Continuous
2 = Phase Mode
1 = Ext. Trig. Lead. Edge
2 = Ext. Trig. Trailing Edge
4 = Main Port String
8 = Auxiliary Port String
16 = Input 2 Leading Edge
32 = Input 2 Trailing Edge
64 = Ethernet String
128 = Ethernet IP Input Leading Edge
256 = Ethernet IP Input Trailing Edge
512 = Fieldbus String
1024 = Fieldbus Input Leading Edge
2048 = Fieldbus Input Trailing Edge
4096 = ID-NET String
1 = Continuous
2 = Multi-Delay
4 = Periodic
8 = Input 2 Leading Edge
16 = Input 2 Trailing Edge
32 = Main Port String
64 = Auxiliary Port String
128 = Ext. Trig. Leading Edge
256 = Ext. Trig. Trailing Edge
512 = Ethernet String
1024 = Ethernet IP Trigger Leading Edge
2048 = Ethernet IP Trigger Trailing Edge
4096 = Fieldbus String
8192 = Fieldbus Input Leading Edge
16384 = Fieldbus Input Trailing Edge
32768 = ID-NET String
0 = Always Enabled
1 = Enabled When Input 2 Open
2 = Enabled When Input 2 Closed
Range: 17 to 60000