Simatic Rf600 - Siemens SIMATIC RF600 System Manual

Hide thumbs Also See for SIMATIC RF600:
Table of Contents

Advertisement

Readers
5.4 RF660R reader
Channel spacing
Modulation methods
Effective radiated power and reading range with RF620A
Effective radiant power
Range
Reading range
Antennas mounted on opposing sides
(portal configuration)
Antennas mounted on the same side
Note
Reading ranges are highly dependent on the transponder type and mounting surface
The reading ranges recommended above are applicable to the RF630L (6GT2810-2AB00,
-2AB01, -2AB02) on card with a 3 m antenna cable (1 dB cable attenuation) and with the
reader set to the maximum power. The RF620A antenna is mounted on a metal surface.
Effective radiated power and reading range with RF660A
Effective radiant power
Range
Reading range
Antennas mounted on opposing sides
(portal configuration)
Antennas mounted on the same side
148
EU: 200 kHz
US: 500 kHz
China: 250 kHz
ASK: DSB modulation & PR-ASK modulation
Encoding, Manchester or Pulse Interval (PIE)
Europe / China
0.1 to 2 W ERP
Europe / China
max. 1 m (recommended
maximum value for
configuration)
max. 1 m (recommended
maximum value for
configuration)
Europe / China
0.1 to 2 W ERP
Europe / China
max. 10 m (recommended
maximum value for
configuration)
max. 10 m (recommended
maximum value for
configuration)
System Manual, 06/2010, J31069-D0171-U001-A10-7618
Draft Version 02.06.2010
USA
0.4 to 4 W EIRP =
0.24 to 2.4 W ERP
USA
max. 1 m (recommended
maximum value for
configuration)
max. 1 m (recommended
maximum value for
configuration)
USA
0.4 to 4 W EIRP =
0.24 to 2.4 W ERP
USA
max. 10 m (recommended
maximum value for
configuration)
max. 10 m (recommended
maximum value for
configuration)