Readers
5.2 RF630R reader
Reading range for China
Antennas mounted on opposing sides
(portal configuration)
Readers mounted on the same side
5.2.5.3
Maximum number of readable tags
The maximum number of readable tags depends on the following parameters:
● Size of the antenna field
● Readability of the tags
For a transmit power of 500 mW ERP, the following is read when the tag RF620T is used:
● Max. 40 tags in the antenna field (tags perpendicular to antenna at 1 m distance). If 2
antennas are used, up to 80 tags can be recognized.
● Max. 18 tags per second
Note for 2-antenna operation
● If 2 antennas are connected to the SIMATIC RF630R, the antennas must be controlled
using the SET-ANT command.
● If 2 antennas are configured as a gate, both antennas should be simultaneously switched
on with the SET-ANT command. The reader multiplexes both antennas internally. The
multiplexing time is 100°ms (internal read time per antenna).
110
3.5 m max. (recommended maximum value for configuration)
2 m max. (recommended maximum value for configuration)
System Manual, 06/2010, J31069-D0171-U001-A10-7618
Draft Version 02.06.2010
SIMATIC RF600