Readers
5.4 RF660R reader
5.4.4.2
Transmission protocols
RS232 communication
Transmission rates
Start bits
Data bits
Parity
Flow control
Stop bits
Ethernet communication
The Ethernet interface offers automatic selection between 10BaseT and 100BaseTX.
Shielded Twisted-Pair patch cables with standard RJ45 connectors are recommended for a
reliable connection.
5.4.5
Technical specifications
5.4.5.1
Mechanical data
Mechanical specification of RF660R
Weight
Dimensions (L x W x H) in mm
Material
Color
Power consumption, typical
Mechanical environmental conditions
Shock
Total shock response spectrum
Vibration
Climatic Conditions
Ambient temperature during operation
Ambient temperature for transport and storage
146
XML protocol
115200 bps
1
8
None
Xon/Xoff
1
3.7 kg
320 x 145 x 100 without connections
Aluminum
Anthracite
24 V
● At 2 W transmit power
● No digital outputs active
ETSI EN 300 019-2-3 V2.1.2
IEC 60068-2-27
Type 3.3
ETSI EN 300 019-2-3 V2.1.2
IEC 60068-2-64
-25 °C to +55 °C
-40 °C to +85 °C
System Manual, 06/2010, J31069-D0171-U001-A10-7618
Draft Version 02.06.2010
800 mA
SIMATIC RF600