Simatic Rf600 - Siemens SIMATIC RF600 System Manual

Hide thumbs Also See for SIMATIC RF600:
Table of Contents

Advertisement

Output Outport (0), (1), (2), (3)
● Each output is rated for 0.5 A current and is electronically protected.
● Four digital outputs can be operated simultaneously with up to 0.5 A each (up to 1.5 A in
total).
● The outputs are optically isolated through optocouplers.
Input Inport (0), (1), (2), (3)
● The inputs are optically isolated through optocouplers.
● The 24 V voltage for the digital inputs (e.g. switches, proximity switches) must be supplied
over a separate cable if electrical isolation is required.
● Level Low 0 ... 3 V; High 3,6 ... 24 V
● Sampling rate < 20 ms
The following diagrams illustrate various connection possibilities.
Voltage infeed through internal source (no electrical isolation)
Figure 5-10
Example circuit 1: Digital inputs
Alternative connection possibilities:
● Pin 2 (VCC) to Pin 9 DI Common
● Pin 1 GND to busbar inputs

SIMATIC RF600

System Manual, 06/2010, J31069-D0171-U001-A10-7618
Draft Version 02.06.2010
Readers
5.3 RF670R reader
119

Advertisement

Table of Contents
loading

Table of Contents