Mounting/installing the device
You can mount the reader in two different ways:
● Via a standardized VESA 100 mounting system using the Antenna Mounting Kit (see
Chapter ). Tighten the M4 screws on the rear of the reader using a maximum torque of ≤
1.3 Nm.
● Directly onto a flat surface.
The positions of the fixing holes for the device are shown in the section Dimension drawings
(Page 131).
5.3.4

Configuration/integration

5.3.4.1

Configuration

An Ethernet interface is available for integrating the device into system environments/networks.
Over the Ethernet interface and with direct connection to the PC, the RF670R can be
configured in two different ways:
● Using RF-MANAGER Basic 2010
● Using RF-MANAGER 2008 Service Pack 3 and higher
The communication interface transfers the data over the RF-MANAGER interface to the IT,
ERP and SCM systems as well as to SIMATIC controllers. Alternatively the data is transferred
to user applications by means of XML commands.
Simple process controls (e.g. a traffic signal) can be directly implemented using the write/read
device via four digital inputs and outputs.
SIMATIC RF600
System Manual, 06/2010, J31069-D0171-U001-A10-7618
Draft Version 02.06.2010
Readers
5.3 RF670R reader
127