Transmission protocols
The following transmission protocols are available: 3964R protocol and TCP/IP.
RS232 communication
Transmission rates
Start bits
Data bits
Parity
Stop bits
RS422 communication
Transmission rate
Start bits
Data bits
Parity
Stop bits
Ethernet communication
The Ethernet interface offers automatic selection between 10BaseT and 100BaseTX.
Shielded Twisted-Pair patch cables with standard RJ45 connectors are recommended for a
reliable connection.
5-12
XML protocol
115200 bps
1
8
Odd
1
3964R protocol
9600, 19200, 38400, 57600, 115200 bps
(autobauding)
1
8
Odd
1