Siemens SIMODRIVE 611 digital Configuration Manual page 189

Drive converters
Hide thumbs Also See for SIMODRIVE 611 digital:
Table of Contents

Advertisement

Aotewell Ltd
05.01
05.08
11.05
Connection
PR module
When supplied:
Connector with a jumper between 1R and 2R
internal resistor active
Thermally conductive
1)
plate
DC link fast
discharge
X151
With internal pulsed resistor
1) Installation, see Chapter 12, Fig. 12-59
Fig. 6-18
© Siemens AG 2008 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 05/2008 Edition
HongKong|UK|China
www.aotewell.com
PR module
X221
50
19
X351
P600
M600
3R
2R
1R
PE
PR module, Order No.: 6SN1113–1AB01–0BAV
Note
Only the external PR 6SL3 100–1BE22–5AA0 can be connected.
Notice
Fast discharge is possible only when a 3–phase AC line supply is present!
sales@aotewell.com
Connecting an external resistor:
Connector without jumper
Internal resistor is not active
External resistor is active
PR module
DC link fast
X221
discharge
50
19
X151
X351
P600
M600
2R
1R
PE
Shield connecting plate
With external pulsed resistor
Industry Automation
6 Infeed Modules
6.7 DC link options
PE
3R
+86-755-8660-6182
6
6-189

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents