5 Control Units
5.2 "SIMODRIVE 611 universal HRS" control board
Optional
PROFIBUS DP
module
X423
Two–color LED
for diagnostics
Fig. 5-7
Optional PROFIBUS DP module
Table 5-8
Which optional modules are available?
Designation
Order No. (MLFB)
PROFIBUS DP2
6SN1114–0NB00–0AA2
Features that
PROFIBUS DP2 and DP3 have in common
PROFIBUS DP3
6SN1114–0NB01–0AA1
5-116
www.aotewell.com
The "SIMODRIVE 611 universal" control board can be connected and operated
as DP slave on the PROFIBUS DP fieldbus when this optional module is used.
S
PROFIBUS ASIC DPC31 without PLL
S
For control boards as of SW 3.1, this module can replace the
optional PROFIBUS DP1 module
S
Requirement:
Control board as of SW 3.1 is required
S
Cyclic data transfer (PKW and PZD section) possible
S
FW module can be updated using SimoCom U
S
Non–cyclic data transfer (DP/V1)
S
"SimoCom U via PROFIBUS" possible
S
PROFIBUS ASIC DPC31 with PLL
S
"Motion Control with PROFIBUS DP" function (clock–synchro-
nous PROFIBUS operation) is possible