PXI/PXIe specifications
NOTE: Specifications are subject to change without notice.
Electrical load regulation specifications
Voltage (V)
+3.3
+12
+5
-12
Chassis cooling specifications
Specification
Module cooling system
Airflow
Pollution specifications
Specifications
Pollution degree
For indoor use only in a climate-controlled environment.
Shock and vibration specifications
Specification
Operational shock
Random vibration
Acoustic emission specifications
Acoustic noise
Acoustic noise specifications for the following base configurations are available.
Table 6: Base configuration 1 (m510)
Component
Cartridge
DIMMs/cartridge
Load regulation (%)
<5
<5
<5
<5
Value
Forced air circulation (positive pressurization)
through three fans with High/Auto speed selector.
Launch Recipe supports this.
From front to rear
Value
2
Value
30 g peak, half-sine, 11 ms pulse
5 Hz to 500 Hz, 0.3 g rms
Quantity
4
4
Specification
m510
Any