Table 4: ASHRAE Class A4 specifications
Specification
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Non-Operating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 125 m (1.8°F per 410
ft) to 900 m (2,953 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per
hour (36°F per hour). No restrictions on product configurations except for rotating hard drives. PCI cards
must be rated for continuous operation with 60°C cooling air. Not rated for operation over 3,030 m
(10,000 ft).
Table 5: Extended Edgeline specifications
Specification
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Non-Operating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per
1,000 ft) to 3,048 m (10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is
20°C per hour (36°F per hour).
50
Specifications
1
1
Value
5°C to 45°C (41°F to 113°F)
-30°C to 60°C (-22°F to 140°F)
8% to 90% at 28°C (82.4°F) maximum wet bulb
temperature
5% to 95% at 38.7°C (101.7°F) maximum wet bulb
temperature
Value
0°C to 55°C (32°F to 131°F)
-30°C to 60°C (-22°F to 140°F)
8% to 90% at 28°C (82.4°F) maximum wet bulb
temperature
5% to 95% at 38.7°C (101.7°F) maximum wet bulb
temperature