2. - INSTALLATION INSTRUCTIONS

The symbols used in the text are explained below:
WARNING
This indication shows the possibility of causing death from electric shock.
WARNING
This indication shows the possibility of causing death or serious injury.
CAUTION
This indication shows the possibility of causing injury or damage to properties only.
i
Symbol for useful information.
IMPORTANT: Wiring procedures and connections shall be in accordance with the national and local codes having jurisdiction.
The warranty of the heater will not cover any damage caused by non observance of any of these instructions.
The installation must be carried out in accordance with the current local electrical regulations. Any installation or
reinstallation has to be carried out by an experienced technician.
Please check that the voltage in the rating label fits the power supply.
This appliance must be grounded.
The appliance should not be installed just below an electrical socket.
The appliance must be installed in such a way that it is impossible for anyone using a bath or shower, to touch the
controls.
If during any installation the thermal insulation shows any sign of damage, it must be replaced.
This heater should be switched off at the circuit breaker before any repair work is carried out. This should also be done
during times of the year when heat is not required.
This appliance is only for permanent connection to a fix installation. After installation a survey of the first charging cycle
should be carried out to ensure that the main input thermostat switches off. Ventilate the room during this first cycle.
Never open a charged heater.
To maintain stability, it is essential that the heater is placed on a level surface and care should be taken to avoid
irregular surfaces, such as may result from carpets or tiled surrounds partially protruding under the heater.
The presence of air particles of smoke, dust and other pollutants could, in time, discolour the walls and surfaces around
the heater.
In order to achieve a correct installation of this device, follow these steps:
1. - Choose the right location to install ECOMBI HHR. The minimum clearances must be respected from the appliance to any
combustible material such as furniture or curtains. To reduce the risk of fire, do not store or use gasoline or other
flammable vapours and liquids in the vicinity of the heater.
2. - Open the carton at the indicated side and install the supporting feet without removing the heater.
Turn the carton upside down to allow the heater to stand on its feet and remove the carton. Check that it is the correct model
and that it is in good conditions.
Check that all parts have been delivered and are intact.
-
1 ECOMBIHHR heater casing.
-
1 bag containing 2 screws and 2 dowels and 4 white screws.
-
2 supporting feet.
-
This guide.
-
1 superior fixing fitting.
-
2 lateral fixing fittings.
i
The casing and storage bricks are supplied separately. Check the supplied bricks packages correspond to the ones
indicated on the heater carton.
i
The heater operation is not affected if bricks with minor damage are used.