Operator Maintenance - JLG 800A Operation And Safety Manual

Boom lift models
Table of Contents

Advertisement

SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
6.3

OPERATOR MAINTENANCE

NOTE: The following numbers correspond to those in Figure 6-
9., Operator Maintenance and Lubrication Diagram.
Table 6-17. Lubrication Specifications
KEY
MPG
Multipurpose Grease having a minimum dripping point of 350° F
(177° C). Excellent water resistance and adhesive qualities, and
being of extreme pressure type.
(Timken OK 40 pounds minimum.)
EPGL
Extreme Pressure Gear Lube (oil) meeting API service classifica-
tion GL-5 or MIL-Spec MIL-L-2105
HO
Hydraulic Oil. API service classification GL-3, e.g. Mobilfluid 424.
EO
Engine (crankcase) Oil. Gas - API SF, SH, SG class, MIL-L-2104.
Diesel - API CC/CD class, MIL-L-2104B/MIL-L-2104C.
IMPORTANT
LUBRICATION INTERVALS ARE BASED ON MACHINE OPERATION
UNDER NORMAL CONDITIONS. FOR MACHINES USED IN MULTI-SHIFT
OPERATIONS AND/OR EXPOSED TO HOSTILE ENVIRONMENTS OR
CONDITIONS, LUBRICATION FREQUENCIES MUST BE INCREASED
ACCORDINGLY.
6-20
SPECIFICATIONS
NOTE: It is recommended as a good practice to replace all filters
at the same time.
1. Swing Bearing - Internal Ball Bearing
Lube Point(s) - 2 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hrs of operation
Comments - Remote Access
– JLG Lift –
3121209

Hide quick links: