E09 / E10
Cause:
Remedy:
E11
Cause:
Remedy:
E018
Cause:
Remedy:
E23
Cause:
Remedy:
No function
The device cannot be switched on
Cause:
Remedy:
No welding current
Device switched on, indicator for the selected welding process is lit
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Impedance load too high on power source output
Use power source correctly (welding)
No communication with the control panel
Contact after-sales service
Wrong firmware (software) has been loaded
Contact after-sales service
A voltage of > 113 V DC has been measured on the welding sockets
Contact after-sales service
Mains switch is faulty
Contact After-Sales Service
Break in the welding cable connection
Check the plug connections
Poor or no earth
Establish a connection to the workpiece
There is a break in the power cable in the welding torch or electrode holder
Replace welding torch or electrode holder
37