E16
Cause:
Remedy:
E18
Cause:
Remedy:
E19 / E22 / E30 / E53 / E83
Cause:
Remedy:
E23
Cause:
Remedy:

No function

The power source cannot be switched on
Cause:
Remedy:
Cause:
Remedy:
Battery is not charged
Power source is connected to the charger, charger is connected to the mains, no
charging indicator on the power source
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Communication error between battery and ACCUPLT / ACCUPLT-
TIG PC board
Contact after-sales service
Wrong firmware (software) has been loaded
Contact after-sales service
Battery fault
Contact After-Sales Service
A voltage of > 113 V DC has been measured on the current sockets
Contact After-Sales Service
The battery has entered a state of deep discharge as it has been
stored for too long without being charged
Charge the battery now
Battery operation is possible again above 25% capacity.
If charging is no longer possible, contact After-Sales Service.
Control panel defective
Contact After-Sales Service
Device is too hot
Check/reduce ambient temperature, allow battery to cool down
Device temperature too low
Check/increase ambient temperature, disconnect and reconnect bat-
tery charger
Charging cable defective
Renew charging cable