Emerson EV1000-2S0004G User Manual page 99

Ev1000 series general purpose variable speed drive
Hide thumbs Also See for EV1000-2S0004G:
Table of Contents

Advertisement

艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312
Para.
Name
F2.11
DC brake current
F2.12
DC brake time at stop
F2.13
Dynamic braking
Ration of braking time
F2.14
to total operating time
Para.
Name
F3.00 Anti-reverse setting
F3.01 FWD/REV transition time 0 ~ 3600s
F3.02 Reserved
F3.03 Reserved
F3.04 Reserved
F3.05 Auto energy saving
F3.06 AVR function
F3.07 Slip compensation gain
Group 2: Start/Brake Parameters
G type: 0~150% of drive's rated current (max. among
the 3 phases),
P type: 0~130% of drive's rated current (max. current
among the 3 phases).
0.0: disabled
0.1~60.0s
0: disabled
1: enabled
0.0 ~ 100.0 %
Group 3: Auxiliary Operating Parameters
Range
0: reverse allowed
1: reverse not allowed
-
-
-
0: disabled
1: enabled
0: disabled
1: always enabled
2: disabled during decelerating
0.0 %~ 300.0 %
EV1000 Series General Purpose Variable Speed Drive User Manual
Range
Unit
1
0.1s
-
-
-
1
1
0.1 %
Appendix 1 Parameter Set
Unit Default Modification
0.1 %
0.0 %
0.1s
0.0s
1
0
0.1 %
2.0 %
Default
0
0.0s
0
0
0
0
2
100.0 %
95
×
×
Modification
×
*
*
*
×
×

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents