Para.
Name
F0.08
Reserved
F0.09
Torque boost
F0.10
Acc time 1
F0.11
Dec time 1
F0.12
Upper limit of
freq.
F0.13
Lower limit of
freq.
F0.14
V/F curve
F0.15
V/F freq. F3
F0.16
V/F voltage V3
F0.17
V/F freq. F2
F0.18
V/F voltage V2
F0.19
V/Ffreq. F1
F0.20
V/F voltage V1
F0.21
Manual torque
boost cutoff point
Group 0: Basic Operating Parameters
-
0: (auto)
0.1 %~ 30.0 %
0.1 ~ 3600
(default unit is second, other options refer to F9.09)
F0.13 ~ F0.05
0.00 ~ F0.12
0: user-defined V/F curve, based on F0.15 ~ F0.20
1: curve1, a 2-order curve
2: curve 2, a 1.7-order curve
3: curve 3, a 1.2-order curve
F0.17 ~ F0.06
F0.18 ~ 100.0 %
F0.19 ~ F0.15
F0.20 ~ F0.16
0.00 ~ F0.17
0 ~ F0.18
0.0 ~ 50.0 % (based on F0.06)
EV1000 Series General Purpose Variable Speed Drive User Manual
Range
Appendix 1 Parameter Set
Min unit
Default
-
-
0.1 %
0.0 %
0.1
6.0s
0.01Hz
50.00Hz
0.01Hz
0.00Hz
1
0
0.01Hz
0.00Hz
0.1 %
0.0 %
0.01Hz
0.00Hz
0.1 %
0.0 %
0.01Hz
0.00Hz
0.1 %
0.0 %
0.1 %
10.0 %
91