92
Appendix 1 Parameter Set
Para.
Name
F1.00
Freq. Curve selection
F1.01
Gain of reference
frequency selector
F1.02
Filter time
F1.03
Max. input pulse freq.
Ratio of Min. input of
F1.04
curve 1 to F1.03
Frequency
F1.05
corresponds to min.
input of curve 1
Ratio of Max. input of
F1.06
curve 1 to F1.03
Frequency
F1.07
corresponds to max.
input of curve 1
Group 1: Reference Frequency
One's place of F1.00: VCI curve selection
0: curve 1
1: curve 2
Ten's place of F1.00: CCI curve selection
0: curve 1
1: curve 2
Hundred's place of F1.00: PULSE curve selection
0: curve 1
1: curve 2
0.00 ~ 9.99
0.01 ~ 50.00s
0.1 ~ 50.0k
0.0 %~ F1.06
0.00 ~ F0.05
F1.04 ~ 100.0 %
0.00 ~ F0.05
EV1000 Series General Purpose Variable Speed Drive User Manual
Range
Unit
Default Modification
1
000
0.01
1.00
0.01s
0.50s
0.1k
10.0k
0.1 %
0.0 %
1
0.00Hz
0.1 %
100.0 %
1
50.00Hz