艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312
Para.
Name
F4.01 Stage 1 setting
F4.02 Stage 1 run time
Group 4: PLC Parameters
One's place of F4.01:
0: select MS frequency 1, (F3.23)
1: decided by F0.00
2: MS close loop setting 1 (F5.20)
3: decided by F5.01
Ten's place of F4.01: running direction
0: forward
1: reverse
2: depends on Run command
Hundred's place of F4.01: Acc/Dec time selection
0: Acc/Dec time 1
1: Acc/Dec 2
2: Acc/Dec 3
3: Acc/Dec 4
0.0 ~ 6500
EV1000 Series General Purpose Variable Speed Drive User Manual
Range
Appendix 1 Parameter Set
Unit Default Modification
1
000
0.1
20.0
99