艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312
Para.
F6.00
Traverse function selection
F6.01
Traverse mode
F6.02
Preset traverse frequency
F6.03
Preset traverse frequency
hold time
F6.04
Traverse amplitude
F6.05
Step freq.
F6.06
Traverse cycle
F6.07
Rise time of triangular wave
Note: ① The central frequency of traverse operation is default as present reference frequency. The
traverse setting becomes invalid for close-loop and jog.
Group 6: Traverse Operating Parameter
Name
0: disabled
1: enabled
One's place of F6.01: transfer mode
0: auto (according to F6.03)
1: terminal configuration (manually)
T
en's place of F6.01: amplitude control
Hundred's place of F6.01: start/stop mode
Thousand's place of F6.01: save traverse
state upon power failure
0.00Hz ~ 650.0Hz
0.0 ~ 3600.0s
0.0 ~ 50.0 % (based on central freq.)
0.0 ~ 50.0 % (based on F6.04)
0.1 ~ 999.9s
0.0 ~ 100.0 % (traverse cycle)
EV1000 Series General Purpose Variable Speed Drive User Manual
Range
0: varied amplitude
1: fixed amplitude
0: start to the state before stop
1: just restart, no other requirement
0: save
1: not save
Appendix 1 Parameter Set
Unit
Default
1
0
1
0000
0.01Hz
0.00Hz
0.1s
0.0s
0.1 %
0.0 %
0.1 %
0.0 %
0.1s
10.0s
0.1 %
50.0 %