Rated output capacity, current, 0~128 Hz 0.5kVA 1.3A Hz 0.5kVA 1.3A Hz 0.5kVA 1.3A Hz 0.5kVA 1.3A frequency range and voltage S/N: Bar code Emerson Network Power Co., Ltd. 1.3 Models Rated input current Rated capacity Rated output Motor power...
Page 3
Installation size External size Installation Weight hole Inverter model (kg) A (mm) B (mm) L (mm) W (mm) H (mm) diameter (mm) EV3200-2S0002A EV3200-2S0002S 172.5 Φ4 EV3200-2S0004A EV3200-2S0004S 1.5 Specifications Items Subitems Specifications Voltage range Single-phase AC power, 180V ~ 264V Input Frequency range 50Hz ±...
Page 4
Items Subitems Specifications Auto tuning of Purpose of auto tuning function of inverter is to obtain the motor's motor's parameters automatically, and these parameters will be parameters saved automatically after the tuning process is over Speed-adjusting Under rated load condition, 1:100 for vector control with speed range sensor;...
Storage -40°C ~ + 70°C temperature Protection IP21 Forced air cooling (EV3200-2S0004A and Structure EV3200-2S0004S) Cooling Natural air cooling (EV3200-2S0002A and EV3200-2S0002S) 2. Operation Function and data switchover key Programming key Save key Digit modification key Shift key Stop key...
In the status of RUN and STOP, press this key to select the Shift parameters that you want to display on the screen; when setting data, press this key to select the digit you want to modify In the keypad control mode, pressing this key opens the door OD key (or initiates forward (FWD) spinning) In the keypad control mode, pressing this key closes the door...
4.Wiring Diagram Of Inverter 4.1 Wiring Diagram Of Inverter MCCB Single phase power supply EV3200 inverter 50/60Hz Light curtain NO input PG: pulse generator Fault relay Safety edge NO input Complete OD relay output OD command input Complete CD CD command input relay output 4.2 ...
Page 8
EV3200 P(+) A amplified view Terminal Function description P ( + ): positive DC bus output terminal; PB: reserved; (-): negative P ( + ), PB, (-) DC bus output terminal U, V, W Motor connection terminal Safety earth point ...
EV3200 PA1 PC1 A amplified view Terminal Terminal function Specifications When F9.22 is 0: normally closed contact output PA1, PC1 When F9.22 is 1: normally open contact output Contact rating When F9.22 is 0: normally closed AC: 250V/1A (cosΦ=0.4), 250V/2A contact output PA2, PC2 When F9.22 is 1: normally open...
6. Switch on the inverter again, in first time operation (OD or CD), the inverter will operate at the speed set by F3.00. When the door is opened or closed completely, the inverter will switch to OD (or CD) completion torque maintaining status. 7.
Frequency F2.04 F2.10 F2.07 F2.00 F2.11 F2.03 F2.02 F2.08 Time CD speed decrease signal CD position limiting signal CD operation curve for speed control 7.Parameter Table Set F9.18 to 3 to restore the factory settings. 7.1 Basic Operation Parameters F0 Min. Parameter Name Setting range Default Mod. unit User 0 ~ 9999 (0000 means no password) ○...
Page 12
Min. Parameter Name Setting range Default Mod. unit 0: same as direction preset by actual motor Running wiring F0.03 direction × 1: reverse to direction preset by actual motor selection wiring Max.output 50.00Hz ~ 128.0Hz 0.01Hz 50.00Hz × F0.04 frequency F0.05 ~ Reserved F0.08...
Page 13
Min. Parameter Name Setting range Default Mod. unit CD start creep time for speed F2.00 10 ~ 9999ms 500ms ○ control F2.01 CD start creep distance 0 ~ 30.0% (door width) ○ F2.02 CD start creep speed 1.00 ~ 25.00Hz 0.01Hz 1.00Hz ○...
Page 14
Min. Parameter Name Setting range Default Mod. unit Position of safety edge lift signal F3.06 0% ~ 40.0% (door width) 0.1% 10.0% × output Function selection of OD upon 0: stop; 1: open the elevator F3.07 × CD obstruction door 0 ~ 150.0% (motor rated F3.08 CD obstruction sensitivity...
Page 15
Min. Parameter Name Setting range Default Mod. unit 0: same as direction preset by PG wiring F4.02 PG direction × 1: reverse to direction preset by PG wiring F4.03 Magnetic pole initial angle 0.0 ~ 359.9° × Speed during door width ×...
Page 16
Min. Defa Parameter Name Setting range unit 0: No functions (can be set repetitively) 1: External reset (RESET) signal input 2: Normally open input contacts for light curtain signal 3: Normally closed input contacts for light curtain signal 4: Normally open input contacts for safety edge 5: Normally closed input contacts for safety edge...
Page 17
Min. Defa Parameter Name Setting range unit Function of 0: Output signal 0 for complete OD programmable (immediately output upon position limiting) F5.05 relay output 1: Output signal 0 for complete CD PA1/PC1 (immediately output upon position limiting) 2: Output signal 1 for complete OD Function of (output after position limiting and lock) programmable...
Page 18
Min. Parameter Name Setting range Default Mod. unit Exciting current with F6.13 0.00 ~ 99.99A 0.01A 0.39 × no load 7.8 Vector Control Parameters F7 Parameter Name Setting range Min. unit Default Mod. ASR proportional gain F7.00 0.000 ~ 6.000 0.001 0.600 ×...
Page 19
Min. Parameter Name Setting range Default Mod. unit 0: RTU, 1 start bit, 8 data bits, 2 stop bits, no parity 1: RTU, 1 start bit, 8 data bits, 1 stop bit, even parity 2: RTU, 1 start bit, 8 data bits, 1 stop bit, odd parity F8.01 Modbus data format...
Page 20
Min. Parameter Name Setting range Default Mod. unit The display of each parameter is controlled by a binary bit. “1” for display: Bit0: running frequency (Hz) Bit1: reference frequency (Hz) Bit2: output voltage (V) Bit3: output current (A) Parameters Bit4: output torque (%) F9.00 displayed by Bit5: DC bus voltage (V)
Page 21
Min. Parameter Name Setting range Default Mod. unit 11: Heatsink overheating (E011) 12: Reserved 13: Inverter overload (E013) 14: Motor protection (E014) 15: Reserved 16: EEPROM read or write fault (E016) 17: Reserved 18: Reserved 19: Current detecting circuit fault (E019) 20 ~ 23: Reserved 24: Motor tuning error (E024)
Page 22
Min. Parameter Name Setting range Default Mod. unit pulse counted for door position at fault time High digit of F9.12 0 ~ 9999 (×10000) OD times Low digit of F9.13 0 ~ 9999 OD times High digit of F9.14 0 ~ 9999 (×10000) CD times Low digit of F9.15...
Page 23
Fault Fault type Possible cause Action to take code 3) Incorrect external wiring 3) Wiring correctly 4) Incorrect wiring of PG 4) Change the setting of 5) Output phase failure F4.02 or the wiring of PG 5) Check the cable connection of the motor 1) Increase Dec time or Overcurrent in...
Page 24
Fault Fault type Possible cause Action to take code current set too small 2) Check the setting of 3) Motor model selection error F6.04 3) Select applicable motor E015 Reserved EEPROM read Fault occurs during the read-write of E016 Seek service or write fault control parameters E017,...
Page 25
Fault Fault type Possible cause Action to take code 3) CD and OD time is set shorter than to a bigger value and all the settings of CD and OD time ensure the setting of F006 4) In the dual motors control mode, is bigger than the sum of tuning is conducted or synchronous all the settings of CD and...