Siemens SIMOVERT MASTERDRIVES Operating Instructions Manual page 57

Cbl-communication board cc-link
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

03.99
Process data
softwiring of actual-
value channel
NOTE
Siemens AG
6SE7087-6NX84-0GB0
SIMOVERT MASTERDRIVES
The actual-value process data (PZDi, i = 1 to 16) are assigned to the
corresponding status words and actual values by means of the indexed
parameter P734.i (CB/TB actual values). Each index stands for an item
of process data.
Parameter
VC
Actual-value channel
connecting actual-values of converter to CBL transmit channel
(ACT VALUE: PZD1...16)
P734.1
P734.2
0148
P734.3
P734.4
P734.5
0021
P734.6
P734.7
0148
P734.8
P734.9
P734.10
P734.11
P734.12
P734.13
P734.14
P734.15
P734.16
CC-Link and the specified data structure for converters handle only 16-
bit values. For using 32-bit connectors refer to documentation of
converter.
Operating Instructions
Contents
Meaning
MC
0032
Mandatory: statusword 1
0151
Mandatory: actual value frequency
0022
Mandatory: actual value output current
0033
Mandatory: statusword 2
0189
Mandatory: actual value output voltage
0070
Mandatory: setpoint frequency
0151
Mandatory: actual value rotation
0024
Mandatory: actual value torque
xxxx
Optional: Optional monitoring value 1
xxxx
Optional: Optional monitoring value 2
xxxx
Optional: Optional monitoring value 3
xxxx
Optional: Optional monitoring value 4
xxxx
Optional: Optional monitoring value 5
xxxx
Optional: Optional monitoring value 6
xxxx
Optional: Optional monitoring value 7
xxxx
Optional: Optional monitoring value 8
Start-up of the CBL
5-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents