Siemens SIMOVERT MASTERDRIVES Operating Instructions Manual page 32

Cbl-communication board cc-link
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Communication via CC-Link
Task
ID
0
No task
1
Request parameter value
2
Change parameter value (word) for non-indexed parameters
3
Change parameter value (double word) for non-indexed parameters
Request descriptive element 1
4
5
Change descriptive element (not with CBL)
Request parameter value (array) 1
6
Change parameter value (array, word) for indexed parameters 2
7
Change parameter value (array, double word) for indexed parameters 2
8
9
Request number of array elements
10
Reserved
Change parameter value (array, double word) and store in the EEPROM 2
11
Change parameter value (array, word) and store in the EEPROM 2
12
13
Change parameter value (double word) and store in the EEPROM
14
Change parameter value (word) and store in the EEPROM
15
Read or change text (not with CBL)
4-12
Reply IDs 11 to 15 are specific to SIMOVERT MASTERDRIVES and
are not defined in the PROFIBUS profile. If the reply ID has the value 7
(task cannot be executed), an error number is placed in parameter
value 1 (PWE1).
Meaning
1 The required element of the parameter description is specified in IND (2nd word)
2 The required element of the indexed parameter is specified in IND (2nd word)
Task ID (master → converter)
Table 4-4
6SE7087-6NX84-0GB0
Operating Instructions
SIMOVERT MASTERDRIVES
03.99
Reply ID
positive
negative
0
7 or 8
1 or 2
1
2
3
3
4 or 5
4
5
6
-
5
4
2
1
15
7 or 8
Siemens AG