03.99
Process data
softwiring of receive
channel
NOTE
Siemens AG
6SE7087-6NX84-0GB0
SIMOVERT MASTERDRIVES
Parameter
Controlword 1
connecting CBL controlword 1 (REF VALUE: PZD1) to converter controlword 1
P554
1)
P555
P565
P568
P569
P571
P572
1) use alternativly P555, P556 or P557 (AND function)
2) check P448 and P449 for JOG speed!
After power-up till data transmission between PLC cpu and CBL the
alarm message A035 will occur and will be displayed (control bits 11
and 12 equals 0!). The duration depends on the converter type and the
configuration (tech board plugged?) and takes some seconds. After
starting data transmission via CC-Link to PLC cpu the alarm will be
automatically cleared.
Parameter
Controlword 2
connecting CBL controlword 2 (REF VALUE: PZD4) to converter controlword 2
P576
P577
P580
P581
P???
P???
P???
Operating Instructions
Contents
Meaning
3100
Mandatory: RUN/STOP
3101
Mandatory: MRS function
3107
Mandatory: reset error flag
3108
Mandatory: JOG mode
3109
Mandatory: JOG mode
3111
Mandatory: STF (Forward)
3112
Mandatory: STR (Reverse)
Contents
Meaning
3400
Mandatory: RT function
3401
Mandatory: RT function
3404
Mandatory: RL, RM, RH
3405
Mandatory: RL, RM, RH
3411
Optional: Optionflag F27
3412
Optional: Optionflag F28
3413
Optional: Optionflag F29
Start-up of the CBL
2)
2)
5-7