4.2.2
If using an LD6 running software version 50.0.0.2 or above, a DC filter unit must be
used. Refer to section 4.2.2.1 for further information.
The DC power connector is a Neutrik NL4FX.
Details on this connector including its termination are below. Alternatively you may use a
Switchcraft HPCC4F connector.
The connector comprises three parts for assembly. The positive connection should be
made to 1+, the negative connection to 1-. Positive terminals (1+ and 2+) should be
linked together inside the connector. Negative terminals (1- and 2-) should also be
linked together inside the connector.
Prepare the cable as shown below (measurements are in millimetres).
These cables are not provided with the equipment as standard however can be
provided pre-assembled by request. Please contact VERIPOS Helpdesk if a
pre-assembled cable is required.
Rev No:
L10
Date:
03.04.2017

DC Power Connector

Figure 27. Neutrik NL4FX power connector
Figure 28. DC power cable preparation