1Pps Output Option; Ethernet Interface - Veripos LD6 Installation Manual

Integrated mobile unit
Hide thumbs Also See for LD6:
Table of Contents

Advertisement

Document title:
LD6 Installation Manual
Document No.
AB-V-MA-00520
LD6 Software version 101.0.0.9 & above
See the Reference information chapter for pin-out details and contact VERIPOS for
advice where required.
3.6.3
Some LD6 variants provide a facility for output of a 1PPS (one pulse per second) signal,
used by external equipment for accurate time synchronisation to navigation systems or
multi-beam sonar.
3.6.4
Two Ethernet RJ45 connectors are fitted on the LD6 rear panel. These can have static or
DHCP addresses (see table below).
Specific guidance for interconnect to vessel equipment can be provided. Contact the
VERIPOS Helpdesk for advice.
The LAN ports have default fixed IP addresses:
When attaching the LD6 directly to the PC, VERIPOS recommend that RJ45 patch
cables using the RJ45 crossover module supplied are attached to the PC LAN port,
which is assigned a fixed IP address of 192.168.2.4 (assuming LD6 LAN1 is used).
Rev No:
L10
Date:
03.04.2017
COM Port
Source
COM1
L-Band
COM2
GNSS
COM3
GNSS
COM4
L-Band
COM5
MF
COM6
UHF

1PPS Output Option

Ethernet Interface

192.168.2.2 (Upper port)
192.168.3.3 (Lower port)
Content
Format
RTCMa
RS232
NMEAa
RS232
Raw
RS232
RTCMb
RS232
RTCM
RS232
RTCM
RS232
Rate (bps)
9600
9600
115200
9600
9600
9600