Document title:
LD6 Installation Manual
Document No.
AB-V-MA-00520
4.2
This section contains details on the AC and DC power connectors and the cable
termination used for connection to antennas.
When working with these connectors and power, please refer to section 1.5 LD6 Safety
summary.
VERIPOS recommend that prefabricated main cables and coaxial tails are used for
connection of antenna to the VERIPOS below decks equipment.
4.2.1
Description
Cord connectors (rewireable)
Screw-on mounting
Connector, pin temperature 70 °C, protection class I
Cable
Substitute for type P587
Approvals
VDE license number: 40010732
UL license number: E96454
CSA license number: 56242
Technical data
Ratings IEC
Ratings UL/CSA
Dielectric strength
Allowable operation temp.
Protection class
Terminal
Connector
Rev No:
L10
Date:
03.04.2017
CABLING AND CONNECTORS
AC Power Connector
Figure 25. IEC Connector C13, Rewireable, Straight
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 2 kVAC between L-N
> 2 kVAC between L/N-PE (1 min/50 Hz)
-25 °C to 70 °C
Suitable for appliances with protection class 1
acc. to IEC 61140
Cable
C13 acc. to IEC/EN 60320-1, UL 498, CSA C22.2
no.42 (for cold conditions) pin-temperature 70 °C, 10 A,
protection class 1