Document title:
LD6 Installation Manual
Document No.
AB-V-MA-00520
4.1.3
AC power input
DC power input
Power consumption
AC power connector
DC power connector
Display
IEC
AC fuse
Manufacturer
Manufacturer's part number
DC fuse
Manufacturer
Manufacturer's part number
4.1.4
Conforms to IEC 60945.
4.1.4.1
Serial ports:
Format:
Interface type:
Baud rates:
See the Reference information chapter for pin-outs.
Not all data streams are compatible with all baud rates.
Rev No:
L10
Date:
03.04.2017

Electrical

Compass Safe Distance

Serial Ports
14 bi-directional (if configured for applicable data stream)
RS232 or RS422 (switchable)
DB9 (via RJ45 to DB9 adaptor)
1200 to 115200
100–240 VAC
12–24 VDC
100 W max.
IEC Connector C13, rewireable, straight
(see the Reference information chapter for
details)
Neutrik NL4FX
9 cm (3.5") colour touchscreen control
60945 EMC certified
T2AH250V
Littlefuse
0215002.P
T10AH250V
Littlefuse
0215010.P