4.

REFERENCE INFORMATION

4.1
This equipment is for indoor use only and meets performance specification within an
ambient temperature range of -15 °C to +55 °C and a maximum relative humidity of 95%.
Equipment complies with EN60945:2002 [5] for "protected" equipment.
Cable specifications: Please refer to the Reference information chapter for details.
4.1.1
All LD6 variants.
Receiver size
Dimensions
Weight (max)
4.1.2
Enclosure material
Operating temperature range
Operating humidity
Storage temperature range
Storage humidity
4.1.2.1
Although the test conditions for the LD6 units provide for a maximum operating
temperature of 55 °C, continuous operation of all electronic components should if
possible take place at ambient temperatures of only 25 °C. This is a prerequisite for long
life and low service costs.
Rev No:
L10
Date:
03.04.2017

TECHNICAL SPECIFICATIONS

Mechanical

Figure 24. LD6 Overview with power inlet warning sign

Environmental

Safety Considerations
2U height
Fit 19" rack
460 mm x 440 mm x 89 mm
10 kg / 25 lb
Aluminium
-15 °C to +55 °C
Up to 95% non-condensing
-20 °C to +60 °C
Up to 95% non-condensing