This section details the type and typical source for power supply to the LD6.
Power requirement of the LD6:
Units are supplied as standard with an IEC C13 rewireable AC power cable. See the
Reference information chapter for details.
Where a DC power supply is to be used on LD6 units running software version 50.0.0.2
or above, an external DC filter unit should be used. Contact VERIPOS if a DC filter unit
is required. Further details of the DC filter unit can be found in section 4.2.2.1.
The units should be connected to a clean-power source and usually the vessels UPS
system.
Contact VERIPOS Helpdesk if advice is needed on power supplies to the LD6.
Rev No:
L10
Date:
03.04.2017

POWER AND CABLING

Input voltage
Power consumption
AC fuse
DC fuse
100–240 VAC, 50/60 Hz or 12–24 VDC
100 W max
250 V / 2 A Time-lag 20 mm T2AH250V
250 V / 10 A Time-lag 20 mm T10AH250V