Emerson Rosemount 3051S Series Reference Manual page 147

Scalable pressure, flow, and level solution with hart protocol
Hide thumbs Also See for Rosemount 3051S Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-4801, Rev FA
October 2010
Figure 7-33. Configure (Alert Setup) Menu Tree
Home
Configure
1 Overview
1 Guided Setup
2 Configure
2 Manual Setup
3 Service Tools
3 Alert Setup
Statistical Process Monitoring
Status
Baseline Configuration
Detection Configuration
Operational Values
Alert Setup
1 Statistical Process
Monitoring
2 Power Advisory Diagnostic
3 Device Diagnostics
Power Advisory Diagnostic
4 Process Alerts
1 Power Advisory Diagnostic
5 Service Alerts
2 Loop Power Characterization
Device Diagnostics
1 mA Output Diagnostic
2 Transmitter Power Consumption
Process Alerts
1 Pressure Alerts
2 Temperature Alerts
Service Alerts
1 Time Remaining
2 Message
3 Alert Mode
4 Configure
5 Reset Alert
Rosemount 3051S Series
Detection Status
1 SPM Status
2 SPM Status (cont.)
3 Standard Deviation Sensitivity*
4 Mean Sensitivity**
Status
*If CV is selected, "Coefficient of Variation Sensitivity"
**If CV is selected, this is not shown
1 Detection Status
2 SPM Control
SPM Control
1 Mode
3 Statistical Values
4 Time Stamp
2 Reset
3 Relearn
5 Trends
Statistical Values
1 Standard Deviation*
2 Mean
*Or Coefficient of Variation
Time Stamp
1 Time Since Detection
2 Total Operating Time
Trends
1 View Standard Deviation Trend*
2 View Mean Trend
*Or Coefficient of Variation
Learn Settings
Baseline Configuration
1 SPM Variable
1 Learn Settings
2 Learn/Monitor Period
2 Verification Criteria
3 Power Interruption Action
4 Low pressure Cut-off *
*Shown only when CV is selected
Verification Criteria
1 Insufficient Variability
2 Standard Deviation Difference
3 Mean Difference
Standard Deviation Change*
1 Standard Deviation Sensitivity
2 Threshold Value**
Detection Configuration
3 Configure Sensitivity
1 Standard Deviation Detection Settings*
4 Action
2 Mean Detection Settings**
5 Alert Delay
*If CV is selected, "Coefficient of Variation
6 High Detection Message
Detection Settings"
7 Low Detection Message
**If CV is selected, this is not shown
* If CV is selected, "Coefficient of Variation Change"
**Shown only if Sensitivity is set to "Custom"
Mean Change**
1 Mean Sensitivity
2 Threshold Value
3 Configure Sensitivity
4 Action
5 Mean Change Message
Operational Values
1 Standard Deviation
**If CV is selected, this is not shown
2 Mean
3 Coefficient of Variation
SPM Detection Values
4 SPM Detection Values
1 Standard Deviation
5 Number of Relearns
2 Mean
6 Reset Relearn Counter
3 Coefficient of Variation
Power Advisory Diagnostic
1 Terminal Voltage
2 Terminal Voltage Deviation Limit
3 Action
4 Reset Alert
Resistance
1 Previous Baseline
Loop Power Characterization
2 Baseline
1 Resistance
2 Power Supply
Power Supply
3 Characterization Time Stamp
1 Previous Baseline
4 Characterize Loop
2 Baseline
Characterization Time Stamp
1 Previous Characterization
2 Time Since Characterization
mA Output Diagnostic
1 Action
2 Reset Alert
Transmitter Power Consumption
1 Action
Alert Settings
2 Reset Alert
1 Alert Mode
2 High Alert Value
Pressure Alerts
3 Low Alert Value
1 View Trend
2 Pressure
3 Alert Settings
Pressure Alert Events
4 Pressure Alert Events
1 High Alert Events
2 Low Alert Events
Temperature Alerts
3 Reset Alert Events
1 View Trend
2 Module Temperature
3 Alert Settings
Alert Settings
4 Module Temperature Alert Events
1 Alert Mode
2 High Alert Value
3 Low Alert Value
Temperature Alert Events
1 High Alert Events
2 Low Alert Events
3 Reset Alert Events
7-43