Pm/Yield Parts Settings; Set-Up Procedure For Replacing The Pm/Yield Parts - Ricoh MP 305 Plus Field Service Manual

Hide thumbs Also See for MP 305 Plus:
Table of Contents

Advertisement

3. Preventive Maintenance

PM/Yield Parts Settings

Set-up Procedure for Replacing the PM/Yield Parts

1.
Enter the SP mode.
2.
Get the SMC log data using one of the following ways:
a) Execute SP5-990-001 to print SMC log data.
b) Execute SP5-992-001 (SMC List Card Save Function) to save SMC log data to an SD card.
3.
In the SMC data, look at the values of the counters in SP7-621-002 and/or -115, to
determine what parts should be replaced.
Refer to the SP table and PM tables in Appendices.
4.
The following parts require the manual new unit detection setting by a predetermined SP.
See the table below:
Item
120K Parts
• 120K parts includes the parts as shown below:
Hot roller, Pressure roller, Hot roller stripper pawls, Hot roller bearing, Pressure roller bearing
• The PCDU detects a new unit automatically. Other parts require the manual new unit detection
setting with the above SPs.
5.
If the value of SP2-701-108 is "0", clear the counter for the 120K parts by SP7-622-115
([PM Counter Reset]-[120K parts]).
6.
Turn OFF the main power.
7.
Perform the parts replacement.
8.
Turn ON the main power.
9.
On the operation panel, look at the PM counters of the parts that you replaced, to make
sure that these counters were reset to 0. (The PM counter values are in SP7-621-002,
and/or -115.) If the PM counter for a unit is not reset, repeat steps 4, 5, and 7.
10.
Exit the SP mode.
138
SP
To detect a new part/unit for these items
automatically, set the value of this SP to "1". Turn
SP2-701-108
OFF then ON the main power to apply the
setting.
Description

Advertisement

Table of Contents
loading

Table of Contents