4. Replacement and Adjustment
15.
Turn ON the main power.
16.
Restore the original settings of the following SPs, referring to the SMC data obtained in
step 2.
• SP5-825-001 does not download the following SP data to the new NVRAM. So you must set
them manually.
a. SP5-985-001 (Device Setting: On Board NIC)
b. SP5-985-002 (Device Setting: On Board USB)
17.
If the security functions (HDD Encryption and HDD Data Overwrite Security) were
applied, set the functions again.
18.
Ask the customer to restore their address book. Or restore the address book data using
SP5-846-052, and ask the customer to ensure the address book data has been restored
properly.
• If you have obtained the backup of the customer's address book data, delete the backup
immediately after the NVRAM replacement to avoid accidentally taking out the customer's
data.
19.
Output the SMC log using one of the following methods:
To print SMC log data, execute SP5-990-001.
To save SMC log data to an SD card, execute SP5-992-001
• Check that the counters are reset.
20.
Make sure that the list output in step 7-1 through step 7-3 matches the destination
information in step 7-4. If not, set it to the setting before replacement.
21.
Execute the process control manually (SP2-011-001).
• Try all the items below if NVRAM upload (SP5-824-001) or download (SP5-825-001)
cannot be done.
• Check the SP values that changed on the SMC you printed out in step 2. Adjust the
values manually. Make sure that the values of SP5-045-001 and SP5-302-002 are the
same as before replacing.
• Replace all PM parts because all PM counters will be reset.
• If a message states that you need an SD card to restore displays after the NVRAM
replacement, create a "SD card for restoration" and restore with the SD card. Refer to
page 121