• The controller board is malfunctioning.
• The harness of the operation panel is disconnected, or the connection is loose.
• The controller's response is slow.
Troubleshooting Procedures
• Turn OFF then ON the main power.
• Check if the operation panel harness is properly connected.
• Check if the controller board is installed correctly,
• Replace the controller board.

SC673-10

Error Name
Operation Panel Flair Communication Error (Smart Operation Panel)
Type
D
Symptoms
This SC is detected when:
• The Smart Operation Panel is communicating with the main machine (this is called "flair
communication"), and there was no response from the main machine.
• SP5-748-201 for Smart Operation Panel is not enabled.
Possible Causes
This SC is detected when the CATS module (controller) cannot respond to the notification from the
monitoring service module (operation panel).
Troubleshooting Procedures
• Turn OFF then ON the main power.
• If SP5748-201 is set to "0" (Not connect), change the value to "1" (Connect).
SC681-01, -06, -11, -16, -21, -26, -31, -36
Error Name
SC681-01: Invalid Device ID
SC681-06: Channel Error
SC681-11: Device Error
SC681-16: Communication Abort Error
SC6xx (Including Controller Service Calls)