Flue restrictor installation
The flue restrictor works by limiting the amount of air required for combustion.
The higher the flue, the more the air is circulated. This can affect the performance
of the fire. Different flue configurations require different positioning of the flue
restrictor—refer to p. 24-25 to determine what setting is required.
3
2
3
2
The different hole positions are shown in
4
1
4
1
the diagram. These are stamped on the flue
restrictor.
Before installing the flue restrictor
Before the flue restrictor can be installed you
need to remove the pilot shield and carefully
lift the burner bed out of the unit.
Attach the flue restrictor as shown by securing with the screws provided.
3
3
2
2
RDV3611 installation guide: 11156-E 05-16 | 13