Command
Lm=n
Set Limit m (where m is defined in the table
shown in the cell above) to the value n.
Note: This command requires the Limit password
(LP) to be set.
LP=n
Set the Limit Password to n. The Limit password
is reset on power-up
ER
Read the Error code for 6300 operational errors.
These are errors different than those returned in
response to a command.
GO
Activate or execute commands that set up various
parameters. Functions exactly like the GO key on
the Remote.
CN
Cancel commands that set up various parameters.
Functions exactly like the CANC key on the
Remote.
GG
Executes the Go-to-Ground function
SF=1
Starts the Self-test function
SF=0
Read the Status of the Self-test as value n per the
table below.
n
0
1
2
3
4
5
6
7
HC
Read the current value for Height correction
HC=n
Set the Height correction value to n
Tm
Read the current value for Leak-Timer m, where
m is 1 to 3.
Tm=n
Set Leak-Timer m to value n
EN
Read the 10-bit Encoder value. The 10-byte
ASCII-string returned has A1 as the MSB and D4
as the LSB. Each byte is either '0' or '1'
FL
Read the Flight level represented by the 10-bit
encoder code. The value is always 3 bytes and is
'xxx' for invalid codes.
CP=n
Set the Calibration password to n.
125-9106A
Description
Self-test status
Self-test passed
Memory test failed
Static measurement system failed
Pitot measurement system failed
Solenoids failed
Pumps failed
Static control system failed
Pitot control system failed
Data sent from
Data sent from
PC
n
0 if OK; or
Error code
n
0 if OK; or
Error code
None
Error code (0 if
no error)
None
0 if OK; or
Error code
None
0 if OK; or
Error code
None
0 if OK; or
Error code
None
0 if OK; or
Error code
None
Status code n
None
Ht.correction
value
n
0 if OK; or
Error code
None
Value of Leak-
Timer m
n
0 if OK; or
Error code
None
10-byte string
indicating
encoder value
None
3-byte string
indicating flight
level
n
0 if OK; or
Error code
6300