Electrical Specifications
Number of isolated
battery bank outputs
Nominal battery voltage
Normal operating output
range
Nominal operating AC
input voltage
Maximum DC output
current (total)
Absorption voltage:
±0.1 V for 12 V units
±0.2 V for 24 V units
975-0401-01-01
TC1012:
1 output
TC1512:
2 separated outputs
TC2012, TC3012, TC4012, TC5012, TC6012,
TC1524, TC2024, TC3024, TC5024:
3 separated outputs
12 V units:12 Vdc
24 V units:24 Vdc
12 V units: 0 – 16 Vdc
24 V units: 0 – 32 Vdc
110 – 250 Vac
TC1012: 10 ±10% A
TC1512: 15 ±10% A
TC2012: 20 ±10% A
TC3012: 30 ±10% A
TC4012: 40 ±10% A
TC5012: 50 ±10% A
TC6012: 60 ±10% A
TC1524: 15 ±10% A
TC2024: 20 ±10% A
TC3024: 30 ±10% A
TC5024: 50 ±10% A
25 °C (77 °F)
Flooded
GEL
AGM
Lead-calcium
Electrical Specifications
12 V units
14.4
14.2
14.3
15.5
24 V units
25 °C (77 °F)
28.8
28.4
28.6
31.0
A–3