SiBE12-712C
3.2

Check Method 2

1. Enter the diagnosis mode.
2. Press the TEMP button.
3. Diagnose by the sound.
4. Enter the diagnosis mode again.
Service Diagnosis
Press the 3 buttons (TEMP▲,TEMP▼, MODE) simultaneously.
The digit of the number of tens blinks.
Try again from the start when the digit does not blink.
Press TEMP▲ or TEMP▼ and change the digit until you hear the sound of "beep" or "pi pi".
"pi" : The number of tens does not accord with the error code.
"pi pi" : The number of tens accords with the error code.
"beep" : The both numbers of tens and units accord with the error code. (
Press the MODE button.
The digit of the number of units blinks.
Service Check Function
(R4272)
(R4273)
(R4274)
See 7.)
(R4275)