Daikin F-Series Service Manual page 40

Inverter multi for 2 rooms
Hide thumbs Also See for F-Series:
Table of Contents

Advertisement

SiBE12-712C
Model
Cooling Capacity
Power Consumption
Running Current
Casing Color
Type
Compressor
Model
Motor Output
Model
Refrigerant Oil
Charge
Type
Refrigerant
Charge
m³/min
Airflow Rates
cfm
Type
Fan
Motor Output
Starting Current
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
(Sound Pressure)
Sound
Sound Power
Liquid
Piping Connection
Gas
Drain
Heat Insulation
No. of Wiring Connection
Max. Interunit Piping Length
Min. Interunit Piping Length
Amount of Additional Charge
Max. Installation Height Difference
Drawing No.
Note:
1. The data are based on the conditions shown in the table below.
Specifications
kW
W
A
W
L
kg
H
M
L
H
M
L
W
A
mm
mm
kg
kg
dBA
dBA
mm
mm
mm
m
m
m
g/m
m
m
Cooling
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB
2AMK40FV1B
Ivory White
Hermetically Sealed Swing Type
1YC23ABXD
600
FVC50K
0.45
R-410A
1.20
36
33
30
1,271
1,165
1,059
Propeller
50
5.9
550×765×285
612×906×362
38
43
47
62
φ
6.4 × 2
φ
9.5 × 2
φ
18.0
Both Liquid and Gas Pipes
3 for Power Supply, 4 for Interunit Wiring
30 (for Total of Each Room)
20 (for One Room)
3 (for One Room)
20 (20m or more)
15 (between Indoor Unit and Outdoor Unit)
7.5 (between Indoor Units)
3D055840A
5m
Specifications
50Hz 220-230-240V
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
29