SiBE12-712C
Turn the breaker ON
• Turning ON the breaker closes the flap. (This is a normal procedure.)
Checks on Remote Controller Settings
• This remote controller is common to the heat pump model
and cooling only model. Use the dipswitches on the remote
controller to set the heat pump model or cooling only model.
• Refer to the following explanation and make the setting as
shown in the illustration.
• For customers of Heat pump model: Set to H/P
• For customers of Cooling-only model: Set to C/O
NOTE
Tips for saving energy
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
• Clogged air filters cause inefficient operation and waste energy.
Clean them once in about every two weeks.
Please note
• The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
• If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
• Use the air conditioner in the following conditions.
Mode
COOL
HEAT
DRY
• Operation outside this humidity or temperature range may cause a safety device to disable the system.
Operation Manual
Operating conditions
Outdoor temperature:〈2MK(X)S40/50〉 10 to 46˚C
〈2MK(X)S52〉 –10 to 46˚C
〈3/4/5MK(X)S〉 –10 to 46˚C
〈RK(X)S〉 –10 to 46˚C
Indoor temperature: 18 to 32˚C
Indoor humidity: 80% max.
Outdoor temperature:〈2MXS40〉 –10 to 24˚C
〈2MXS50/52〉 –15 to 24˚C
〈3/4/5MXS〉 –15 to 24˚C
〈RXS〉 –15 to 24˚C
Indoor temperature: 10 to 30˚C
Outdoor temperature:〈2MK(X)S40/50〉 10 to 46˚C
〈2MK(X)S52〉 –10 to 46˚C
〈3/4/5MK(X)S〉 –10 to 46˚C
〈RK(X)S〉 –10 to 46˚C
Indoor temperature: 18 to 32˚C
Indoor humidity: 80% max.
Dipswitches
H/P
Recommended temperature setting
For cooling:26˚C – 28˚C
For heating:20˚C – 24˚C
If operation is continued out of this range
• A safety device may work to stop the operation.
(In multi system, it may work to stop the operation of
the outdoor unit only.)
• Condensation may occur on the indoor unit and drip.
• A safety device may work to stop the operation.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.
Instruction
C/O
9
177