Daikin F-Series Service Manual page 272

Inverter multi for 2 rooms
Hide thumbs Also See for F-Series:
Table of Contents

Advertisement

SiBE12-712C
Step
11
Detach the discharge
pipe thermistor.
12
Disconnect the
connector for the
thermistor ASSY. [S90]
13
Undo the wire clamp for
the thermistor ASSY
under the electrical box.
Loosen the screw on
14
the right side of the
electrical box.
Removal Procedure
Procedure
Clip for discharge pipe
thermistor
Discharge pipe thermistor
[S90]
Points
Meet the edge of the
thermistor and the clip.
Be careful not to lose the clip
for the discharge pipe
thermistor.
(R7586)
[S90] : Thermistor ASSY
(Outdoor air, Heat
exchanger, Discharge
pipe)
(R7587)
Wire clamp
(R7588)
(R7589)
Outdoor Unit
261