Specifications
Model
Rated Capacity
Front Panel Color
m³/min
Airflow Rates
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power
H
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Model
Rated Capacity
Front Panel Color
m³/min
Airflow Rates
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power
H
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
36
ATXG25EV1B
Cooling
2.5kW Class
Mat Crystal White
H
7.7 (271)
M
6.1 (215)
L
4.7 (165)
SL
3.8 (134)
Cross Flow Fan
W
Steps
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
A
0.15-0.14-0.13
W
30
%
90.9-93.2-96.2
Microcomputer Control
mm
275×840×150
mm
222×894×345
kg
kg
dBA
38/32/25/22
dBA
56
Both Liquid and Gas Pipes
φ
mm
φ
mm
φ
mm
18.0
3D051107
Cooling
H
11.3 (398)
M
9.1 (320)
L
7.1 (250)
SL
6.7 (236)
W
Steps
A
0.15-0.14-0.13
W
%
90.9-93.2-96.2
mm
mm
kg
kg
dBA
47/41/35/32
dBA
mm
mm
mm
Heating
9.0 (317)
7.9 (278)
6.7 (236)
5.4 (190)
40
0.15-0.14-0.13
30
90.9-93.2-96.2
9
13
38/33/28/25
56
6.4
9.5
ATXG50EV1B
5.0kW Class
Mat Crystal White
Cross Flow Fan
40
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
30
Microcomputer Control
275×840×150
222×894×345
9
13
64
Both Liquid and Gas Pipes
φ
6.4
φ
12.7
φ
18.0
3D051109
SiBE12-712C
50Hz 220-230-240V
ATXG35EV1B
Cooling
Heating
3.5kW Class
Mat Crystal White
8.1 (285)
9.6 (338)
6.5 (229)
8.2 (289)
4.9 (173)
6.7 (236)
4.1 (144)
5.9 (208)
Cross Flow Fan
40
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable-Washable-Mildew Proof
0.15-0.14-0.13
0.15-0.14-0.13
30
30
90.9-93.2-96.2
90.9-93.2-96.2
Microcomputer Control
275×840×150
222×894×345
9
13
39/33/26/23
39/34/29/26
57
57
Both Liquid and Gas Pipes
φ
6.4
φ
9.5
φ
18.0
3D051108
Heating
12.6 (444)
10.6 (373)
8.7 (306)
7.7 (271)
0.15-0.14-0.13
30
90.9-93.2-96.2
47/41/35/32
64
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3