2.2.4 Digital Inputs/Outputs

DI/DO are four sets of separate signal on the terminals.
D/I type: A photo-coupler that can be used to monitor external devices.
For example, a button can be used to activate and open a door.
DI wiring allows four groups of signals and is done through JP3.
DI Group No.
DIN1 (Default)
DIN2
DIN3
DIN4

Table 12: D/I groups

D/O type: A relay that can be used to control external devices.
For example, an alarm can be activated for alerting abnormal status.
Or, a door lock switch to lock the door for a certain condition.
DO wiring allows four groups of signals and is done through JP2.
DO Group No.
DO1 (Default)
DO2
DO3
DO4

Table 13: D/O groups

34
Installing 5000/5100:
DI via JP3
Pin No. (+)
Pin No. (–)
2
3
4
5
6
7
8
9
DO via JP2
Pin No.
Pin No. (Common)
(Normal Open)
17
14
11
8
Pin No. (+5V)
1
1
1
1
18
15
12
9
Wiring
Pin No. (GND)
17 or 12
17 or 12
17 or 12
17 or 12
Pin No.
(Normal Close)
19
16
13
10

Hide quick links: