Ricoh MV310 Service Manual page 147

Hide thumbs Also See for MV310:
Table of Contents

Advertisement

May 22nd, 1995
G3 Switch 02
No
FUNCTION
G3 protocol mode used
0: Standard and
0
non-standard
1: Standard only
1
Not used
to
4
Use of modem rate history
during AI short protocol
0: Disabled
5
1: Enabled
AI short protocol
6
(transmission and reception)
0: Disabled 1: Enabled
7
Not used
G3 Switch 03
No
FUNCTION
DIS detection number
(Echo countermeasure)
0
0: 1
1: 2
1
Not used
2
ECM frame size in tx (bytes)
3
0: 256
1: 64
CTC transmission conditions
0: Ricoh mode (PPR x 1)
4
1: ITU-T mode (PPR x 4)
Modem rate used for the
next page after receiving a
5
negative code (RTN or PIN)
0: No change 1: Fallback
6
Not used
7
SERVICE TABLES AND PROCEDURES
COMMENTS
1: Disables NSF/NSS signals (these are used in
non-standard mode communication)
Do not change the settings.
0: Communications using AI short protocol always start
with the highest modem rate.
1: The machine uses the modem rate history for
communications with the same machine when
determining the most suitable rate for the current
communication.
Refer to Appendix B in the Group 3 Facsimile Manual
for details on AI short protocol.
Do not change the setting.
COMMENTS
0: The machine will hang up if it receives the same DIS
frame twice.
1: Before sending DCS, the machine will wait for the
second DIS which is caused by echo on the line.
Do not change the setting.
1: The machine transmits with a frame size of 64 bytes
in ECM. Set this bit to 1 when the other terminal has
only a 64 byte ECM frame size.
When using ECM, the machine will choose a slower
modem rate after receiving PPR once (Ricoh mode) or
four times (ITU-T mode).
ITU-T: New acronym for the CCITT.
1: The machine's tx modem rate will fall back before
sending the next page if a negative code is received.
This bit is ignored if ECM is being used.
Do not change the setting.
4-39
BIT SWITCHES

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents